Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13607290
| No.13607290
- Product Categories
- Friendly Links
| Information Name: | Guangdong medical wastewater treatment _ _ medical wastewater rich students |
| Published: | 2014-11-19 |
| Validity: | 0 |
| Specifications: | Any |
| Quantity: | |
| Price Description: | |
| Detailed Product Description: | Goal to make medical wastewater discharge medical waste prevention to meet the state standard medical wastewater pathogens are: pathogenic bacteria, enteric viruses, worms and protozoa four eggs. Specifically including Sarbanes-Oxley genus Shigella, Vibrio cholerae, pathogenic E. coli, infectious hepatitis virus, polio virus, Coxsackie virus, Ascaris, hookworm eggs, schistosome eggs, amoeba. Most of China's total number of bacteria in medical wastewater million to children up to tens of millions of children per milliliter, which coliform insult ml sewage mostly in the 200,000 or more, intestinal bacteria detection rate of 30% -100%, hospital insult Days discharged hundreds of tons of medical waste containing infectious pathogens, such as not timely disposal of medical waste wastewater discharge, after the adoption of municipal sewers into the sewage treatment plant, resulting in a decline in water quality after treatment of medical waste, affecting people's health. A potential source of infection for the most dangerous of these diseases, and only through sewage treatment, testing out from the sewage before being discovered and stopped. Prevention is the primary goal of medical waste pollution prevention and treatment of medical waste. Specifically, Guangdong medical wastewater treatment, is to make medical wastewater emissions to meet state standards. 1983 China formulated the medical wastewater discharge standard (GBJ48-83), provides that: (1) may not be detected intestinal bacteria and Mycobacterium tuberculosis. (2) shall not be greater than total coliforms per liter 500. (3) Chlorine: General Hospital 4 -5mg / l; containing TB sewage 6-8mg / l. Medical waste treatment facilities should be installed for strengthening supervision of manual processing, wastewater treatment facilities on a regular basis for acceptance of medical monitoring to ensure meet the state standards. Means Dongguan People's Hospital medical waste Medical waste prevention project is to improve the health of students rich wastewater treatment facilities. The hospital should be built sewage treatment station, prohibited the use of seepage wells or sewage pits. Scale medical wastewater treatment station, usually by one ton per bed per day sewage flow design and construction, hospital for infectious diseases and tuberculosis hospitals and more than the average amount of sewage, according to 1.2 tons per bed daily sewage flow design and construction. Medical waste treatment station should be set apart green protective belt and buildings. Sewage treatment plant should be corrosion, leakage facilities; ensure that the treatment effect, safe and durable; easy to operate, easy to disinfect and Qingtao, and contribute to labor protection of the operator. Emergency facilities should be available when a fault occurs, add spare chlorine dioxide disinfection machine, using chlorine disinfection of medical waste must be put in liquid chlorine treatment process through the chlorinator is prohibited sewage directly to the cylinder to put chlorine. Pretreatment medical wastewater treatment methods and types can be mechanical biological treatment. Purely mechanical treatment method known as a treatment, mechanical treatment and biological treatment Combination called secondary treatment. Medical waste must implement a treatment; conditional region should implement secondary treatment. Should strengthen research sludge treatment and disposal methods, rational and effective treatment sludge, making it the biggest play performance. Medical waste water treatment station can set the volume of quantitative chlorination method to put chlorine in the wet sludge, stir, total residual chlorine in the sludge reaches 6 ^ -8mg / L, reduce the secondary pollution to the environment. Rich students Guangzhou Baiyunshan Pharmaceutical wastewater treatment works Guangdong medical wastewater treatment _ _ medical students rich wastewater provided by the Guangzhou Environmental Protection Engineering Co., Ltd. Fu students. Guangzhou Fu students Environmental Engineering Co., Ltd. (www.fsyhb.com) provide customers with "sewage treatment equipment, water purification equipment, dust noise cancellation equipment, disinfection equipment, solid waste handling equipment", and other services, the company has "rich students" and other brands . Focus on environmental monitoring equipment and other industries, in Guangzhou have higher visibility. Welcomes inquiries, contact: Hu large reed. |
Admin>>>
You are the 50601 visitor
Copyright © GuangDong ICP No. 10089450, Environmental Protection Engineering Co., Ltd. Guangzhou Fu students All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 50601 visitor
Copyright © GuangDong ICP No. 10089450, Environmental Protection Engineering Co., Ltd. Guangzhou Fu students All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

